Ziegler Products:
90° Analog Panel Meters Types :
Sr.No Description Scale Type of instrument Type of instrument
White Black
1. Moving Iron Instrument for AC Voltage/ Current Measurement 90° DE EQ
2. Moving Coil Instrument for DC Voltage/ Current Measurement 90° DS PQ
3.

Moving Coil Instrument With Rectifier for AC Voltage/ Current
Measurement

90° DG DQ
4. Moving Coil Instrument With built in Transducer for Active/ Reactive Power
Measurement
90° LM WQ
5. Moving Coil Instrument with built in Transducer for Power Factor Measurement. 90° LF CQ
6. Moving Coil Instrument with built in Transducer for FREQUENCY Measurement. 90° FM ZQ
7. Bi-Metallic Ammeter for Maximum Demand Current Measurement. 90° BM BIQ
8. Bi-Metallic Ammeter Combined with Moving Iron Movement for Simultaneous Maximum Demand Current and Instantaneous Current Measurement. 90° EB BIEQ
  Techinical Data :
                 
TYPE OF
INSTRUMENT
Moving
iron
Moving
coil
Moving coil
with Rectifier
Movingcoil
withbuilt-in-
transducer
for power (active
orreactive)
Moving coil
withbuilt-in-
transducer
for power factor
Moving coil
withbuilt-
intransducer
for frequency
Bimetal
Ammeter
Bimetal
Ammeter
withmoving
iron movement
Ziegler (DE/EQ) (DS/PQ) (DG/VQ) (LM/WQ) (LF/EQ) (FM/ZQ) (BM/BIQ) (EB/BIEQ)
Sizes (in mm) 48 X 48
72 X 72
96 X 96
144 X 144
48 X 48
72 X 72
96 X 96
144 X 144
48 X 48
72 X 72
96 X 96
144 X 144
96 X 96
144 X 144
72 X 72
96 X 96
144 X 144
48 X 48
72 X 72
96 X 96
144 X 144
72 X 72
96 X 96
72 X 72
96 X 96
Measured
quantity
a) Alternating
     current
b) Alternating
     voltage
a) Direct
  current
b) Direct
voltage
a) Alternating
current
b) Alternating
voltage
Power for all types of network & loading

Power factor for all types of single phase & 3-phase
networks

Frequency for
all types of
networks
Mean RMS
value and
maximum
value of current
Mean RMS value,
maximum value &
instantaneous
RMS value of current
Depth behind
bezel

<30 A = 53mm >30A to 60A =60mm
>60 A = 67mm

< 6A = 53mm
> 6A to 60A
= 67mm
>60A =78mm
53 mm 105mm & 131
mm for 3-phase 4 wire
unbalanced loads
53 mm 53 mm 53 mm 53 mm
Range Of
measuremen
t
Current
100mA - 100A (for 48 x 48 upto 60A)

Current
15A -100A
(for 48x48
upto 60A)

Current
100A -100mA
Voltage
6V -600V
Related to rated Current
1A - 5A
&
Voltage
57.7V-500V
Related to rated Current
1A - 5A
Voltage
57.7V -500V
Related to rated Voltage
57.7V - 500V
&
Frequency 45Hz-440Hz
1A & 5A
8 Mins.
Or
15 Mins.
1A & 5A
8 Mins.
Or
15 Mins.
Voltage
6V -750V
(for 48 x 48 upto 600V)
Voltage
15mV-600V
Proof voltage 3.25 kV a.c.
(2.2kV ac for
48)
3.25 kV a.c.
(2.2kV ac for 48)
3.25 kV a.c.
(2.2kV ac for
48)
2.2 kV a.c. 2.2 kV a.c. 2.2 kV a.c. 3.25 kV a.c. 3.25 kV a.c.
Weight(Approx)
(In kgs.)
48 X 48=0.12
72 X 72=0.20
96 X 96=0.25
144 x 144= 0.30
48 X 48=0.12
72 X 72=0.20
96 X 96=0.25
144 x 144= 0.30
48 X 48=0.12
72 X 72=0.20
96 X 96=0.25
144 x 144= 0.30
96 X 96 =
0.65-1.10
144 x 144=
0.85-1.30
96 X 96=0.32
144 x144 = 0.52
72 X 72=0.25
96 X 96=0.30
144 X144= 0.60
72 X 72=0.20
96 X96= 0.25
72 X 72=0.30
96 X96= 0.35
Shunt resistors Shunt resistors are available for D.C. Measurement with minimum Nominal current = 5A,maximum = 7500 A and voltage drop being (1) 50mV (2) 60 mV (3) 75 mV (4) 150 mV  
  Refer Data Sheet for detail specification
 
Housing
Dimensions and panel cutouts conform to IEC 473, DIN 43700.
Housing made of Glass filled polycarbonate, self-extinguishing
and non-drip as per UL 94 V-0
Bezel Slim-line Bezel, black, optional colour other than black(red,yellow,blue,grey)
possible on request.
Glass
Faceplate

Standard-Float Glass faceplate
Optional-Antiglare Glass faceplate, Polycarbonate (shatter proof) faceplate

Installation

Installation in switchboard panels, mosaic arrangement on equipment or machines of wall thickness up to 25 mm for in-line horizontal or vertical arrangement, 40mm for Ziegler meters

Mounting
Fasteners

Standard : ‘S’ Type screw clamp
Options : Leaf spring for control panel thickness of >1 mm, Swivel screw are used for Ziegler meters

Protection

Terminal :IP 20 protection as per IEC 529.
Front Housing Panel: IP 52 Protection as per IEC 529.
Optional:IP 54

Temperature
Range

Operating : -10°C.... +55°C , Storage: -25°C.......+65°C
(as per IEC 51 & EN 60051-1)

Accuracy +/- 1.5 % As per IEC 51 & EN 60051

Vibration &
Shock

10 Hz -55 Hz - 10 Hz 0.15 mm
147 m/s2 (15 g ), 11 ms as per IEC 51 & EN 60051-1

Installation
Cat.

600 V CAT III (IEC 1010), (EN 61010)

Installation
Group

Insulation resistance more than 5 M omega at 500 V as per VDE 0410

Scale
Length

For 90
48=41mm, 72=61mm, 96=97mm, 144=146mm

 
 
© 2006. All rights reserved Ziegler Instruments.