Multi Transducers
Simultaneously acquire several variables from heavy-current power systems. They allow for complete monitoring of 4-wire three phase system with asynchronous load .
FREELY CONFIGURABLE
The following can be configured without change in any hardware with MXX software:
Define the application
Configure rated values for input variables
Select measured variable type and range
Define response characteristics for each individual output variable
Store configuration to memory
MEASURED VARIABLES
Current and voltage (RMS)
Active, reactive and apparent
Active, reactive and apparent energy, counter function
Cosø, Sinø and power factor
RMS current value with long response time (bimetallic measuring function)
Slave pointer function for the measurement of IBs
Frequency
Mean current value with preceding sign for active power (line only)
Beyond this the software provides
A whole series of extras which simplify measuring transducer operation and handling.
This support services include the following ancillary functions :
The configuration stored to the measuring transducer can be queried and printed out as a report.
Power system check : display of measurable variables, ideal for checking for correct connection (RS 232 only)
Simulation of analog outputs(RS 232)
Nameplate print-out
Display of measured variables at the PC monitor:
Analog output values (RS 232)
All selected bus qualities from the queried transducer (RS 485)
Selection of bus variables to be analyzed, which can be queried via the MODBUS interface (RS 485),as well as device address and transmission parameters
Possible switch-over: Frequency measurement via current or voltage path
Slave pointer for output and bus variables can be reset(RS 485)
Measured variabled variables can be selected from 4 internal counters
Password protection for selectable functions which can be used to modify measuring transducer data.
Programmable Multi Transducer
Software for Ziegler M40
Special software for the analysis of measurement values which can be queried via the RS 485 MODBUS interface.
IMPORTANT FEATURES:
Simultaneous acquisition of up to 10 measurement values-can be acquired from selectable measuring transducers along with date and time.
Additional recording of minimum and maximum values is also possible.
Continuous recording of up to 4 measurement values, can also be displayed in analog indicator format
Freely selectable interval for measurement value acquisition
Measurement values can be printed out in tabular form, or as a curve
Recorded measurement values can be exported and saved to other WINDOWS programs
Simple, clear-cut parameters configuration
Recorded values can be saved to memory for frequency used settings
|

|