Multi Transducers

Simultaneously acquire several variables from heavy-current power systems. They allow for complete monitoring of 4-wire three phase system with asynchronous load .

FREELY CONFIGURABLE
The following can be configured without change in any hardware with MXX software:

  • Define the application
  • Configure rated values for input variables
  • Select measured variable type and range
  • Define response characteristics for each individual output variable
  • Store configuration to memory
  • MEASURED VARIABLES

  • Current and voltage (RMS)
  • Active, reactive and apparent
  • Active, reactive and apparent energy, counter function
  • Cosø, Sinø and power factor
  • RMS current value with long response time (bimetallic measuring function)
  • Slave pointer function for the measurement of IBs
  • Frequency
  • Mean current value with preceding sign for active power (line only)
  • Beyond this the software provides
    A whole series of extras which simplify measuring transducer operation and handling.

    This support services include the following ancillary functions :

  • The configuration stored to the measuring transducer can be queried and printed     out as a report.
  • Power system check : display of measurable variables, ideal for checking for correct     connection (RS 232 only)
  • Simulation of analog outputs(RS 232)
  • Nameplate print-out
  • Display of measured variables at the PC monitor:      
          Analog output values (RS 232)
          All selected bus qualities from the queried transducer (RS 485)
         
  • Selection of bus variables to be analyzed, which can be queried via the MODBUS     interface (RS 485),as well as device address and transmission parameters
  • Possible switch-over: Frequency measurement via current or voltage path
  • Slave pointer for output and bus variables can be reset(RS 485)
  • Measured variabled variables can be selected from 4 internal counters
  • Password protection for selectable functions which can be used to modify measuring     transducer data.
  • Programmable Multi Transducer

    Software for Ziegler M40
    Special software for the analysis of measurement values which can be queried via the RS 485 MODBUS interface.

    IMPORTANT FEATURES:

  • Simultaneous acquisition of up to 10 measurement values-can be acquired from     selectable measuring transducers along with date and time.
  • Additional recording of minimum and maximum values is also possible.
  • Continuous recording of up to 4 measurement values, can also be displayed in     analog indicator format
  • Freely selectable interval for measurement value acquisition
  • Measurement values can be printed out in tabular form, or as a curve
  • Recorded measurement values can be exported and saved to other WINDOWS     programs
  • Simple, clear-cut parameters configuration
  • Recorded values can be saved to memory for frequency used settings
  •  